Patroit ESE Lightning Arrester Pakistan

In stock

A Patroit Early Streamer Emission Lightning Arrester is an active lightning rod based on Early Streamer Emission (ESE) technology.

Product: Patroit ESE Lightning Arrester
Available Models: Patroit PRO and ECO+PLUS
Supplier: Electric Power Engineering (EPEPK)
Location: Lahore, Pakistan
Supply Area: Nationwide Pakistan
Phone: +92 300 9444974

An ESE lightning arrester is installed as part of an external lightning protection system to provide a designated air termination point for lightning interception. The system works together with suitable down conductors, earthing, bonding, and structural protection arrangements.

Patroit Lightning Rods are designed with an active ESE operating principle and are available in different models and protection radius configurations.

Description

Description

Patroit ESE Lightning Arrester in Pakistan | Price, Specifications & Coverage Area

Electric Power Engineering (EPEPK) is an authorized dealer and supplier of Patroit ESE Lightning Arresters in Pakistan for commercial buildings, industrial facilities, factories, warehouses, institutions, and other structures requiring external lightning protection.

Patroit Lightning Rods are Early Streamer Emission (ESE) active lightning protection devices designed to provide a designated point for lightning interception as part of a complete lightning protection system.

The Patroit product range supplied by Electric Power Engineering includes the Patroit PRO ESE Active Lightning Rod and Patroit ECO+PLUS Active Lightning Rod models. Both models are documented in the manufacturer’s technical brochures with product dimensions, construction details, protection radius information, and certification references.

If you are looking for a Patroit lightning arrester price in Pakistan, technical specifications, coverage area, or supply information, contact Electric Power Engineering for project-based assistance and quotations.

Patroit ESE Lightning Arrester Price in Pakistan

The price of a Patroit ESE Lightning Arrester in Pakistan depends on the selected model, required protection radius, installation height, protection level, and associated lightning protection components. In addition, several project-specific factors may affect the total cost.

Factors that may affect the total project cost include:

  • PRO or ECO+PLUS model selection
  • Required protection coverage
  • Building height and structure
  • Mounting mast and accessories
  • Down conductors
  • Earthing system requirements
  • Installation location
  • Project-specific technical specifications

Because every building has different lightning protection requirements, selecting an arrester solely on price is not recommended.

Patroit ESE Lightning Arrester Models Supplied by EPEPK

Electric Power Engineering supplies Patroit ESE Active Lightning Rod products in Pakistan, including the PRO and ECO+PLUS series.

Patroit PRO ESE Active Lightning Rod

PRO ESE Active Lightning Rod is designed for external lightning protection applications requiring different protection radius options.

The manufacturer brochure identifies the PRO series as an active Early Streamer Emission lightning rod with stainless chrome/INOX construction, IP67 protection index, and NF/C 17-102 certification reference.

Patroit PRO Lightning Rod Specifications

Specification Details
Product Name Patroit PRO ESE Active Lightning Rod
Product Code PRO
Working Principle Early Streamer Emission (ESE)
ESE Warning Time 60 µs
Certificate Reference NC/NF/C 17-102
Protection Index IP67
Physical Structure Stainless Chrome / INOX
Length 550 mm
Cylinder Diameter 145 mm
Rod Diameter 20 mm
Weight 2.65 kg
Packaging Dimensions 160 × 160 × 600 mm
Available Models PRO 20, PRO 30, PRO 45, PRO 60

Patroit PRO Protection Radius

The following protection radius values are provided in the Patroit PRO technical brochure and are based on a 5-meter installation height. However, these values should be considered alongside the building’s height, installation conditions, required protection level, and complete lightning protection design.

Model Level 1 Level 2 Level 3 Level 4
Patroit PRO 20 31 m 35 m 39 m 42 m
Patroit PRO 30 48 m 52 m 58 m 64 m
Patroit PRO 45 63 m 69 m 78 m 85 m
Patroit PRO 60 79 m 86 m 97 m 107 m

These values should be considered alongside the building’s height, installation conditions, required protection level, and complete lightning protection design.

Patroit ECO+PLUS ESE Active Lightning Rod

The ECO+PLUS ESE Active Lightning Rod is another product series supplied by Electric Power Engineering for external lightning protection applications.

The ECO+PLUS model features stainless chrome/INOX construction, IP67 protection index, and an ESE operating principle documented in the manufacturer technical brochure. In addition, it is available in multiple protection radius configurations for different project requirements.

Patroit ECO+PLUS Lightning Rod Specifications

Specification Details
Product Name Patroit ECO+PLUS Active Lightning Rod
Product Code ECO+PLUS
Working Principle Early Streamer Emission (ESE)
ESE Warning Time 59 µs
Certificate Reference NC/NF/C 17-102
Protection Index IP67
Physical Structure Stainless Chrome / INOX
Length 540 mm
Cylinder Diameter 105 mm
Rod Diameter 20 mm
Weight 2.70 kg
Packaging Dimensions 120 × 120 × 550 mm
Available Models ECO+PLUS 20, ECO+PLUS 30, ECO+PLUS 45, ECO+PLUS 60

Patroit ECO+PLUS Protection Radius

The following protection radius values are based on the Patroit ECO+PLUS technical brochure at a 5-meter installation height.

Model Level 1 Level 2 Level 3 Level 4
Patroit ECO+PLUS 20 25 m 28 m 32 m 35 m
Patroit ECO+PLUS 30 37 m 42 m 48 m 53 m
Patroit ECO+PLUS 45 50 m 56 m 64 m 71 m
Patroit ECO+PLUS 60 62 m 70 m 80 m 88 m

Therefore, the appropriate model should be selected according to project requirements rather than protection radius alone.

Patroit ESE Lightning Arrester Coverage Area

The coverage area of a Patroit ESE Lightning Arrester depends on the selected model, installation height, protection level, and building design.

The Patroit PRO and ECO+PLUS series offer different protection radius options. For example, the manufacturer technical brochures provide separate radius values for PRO 20, PRO 30, PRO 45, PRO 60, ECO+PLUS 20, ECO+PLUS 30, ECO+PLUS 45, and ECO+PLUS 60 models.

A higher model number does not automatically mean that it is suitable for every project. Therefore, the required lightning protection coverage should be evaluated based on:

  • Building height
  • Building footprint
  • Installation height of the air terminal
  • Required lightning protection level
  • Surrounding structures
  • Earthing and down-conductor arrangement
  • Applicable project design requirements

For this reason, professional product selection is recommended for commercial and industrial buildings.

Patroit Lightning Arrester Specifications and Technical Features

Patroit ESE Lightning Arresters are manufactured with technical features documented in the supplied product brochures.

Important product characteristics include:

  • Early Streamer Emission operating principle.
  • Stainless Chrome / INOX physical construction.
  • IP67 protection index.
  • Multiple model options.
  • Different protection radius configurations.
  • Compact product design for assembly and logistics.
  • Product-specific ESE warning time.
  • Certification references including NC/NF/C 17-102.
  • Product testing and technical documentation references.

The Patroit brochures also display references to ISO 9001, ISO 14001, ISO 45001, ISO 10002, CE, and NC/NF/C 17-102 certification markings. Customers requiring technical submittals should request the latest applicable manufacturer documentation for their project.

For Building Protection

A lightning arrester for building protection is part of an external lightning protection arrangement designed to help protect structures exposed to lightning activity.

Patroit ESE Lightning Arresters may be considered for various building and infrastructure applications.

  • Commercial Buildings
  • Industrial Facilities
  • Institutional Buildings
  • Other Infrastructure Applications

Patroit Lightning Protection System Components

A Patroit ESE Lightning Arrester is not intended to function as a complete lightning protection system by itself.

A properly designed external lightning protection system may include several interconnected components.

Electric Power Engineering also supplies earthing and lightning protection materials for complete electrical project requirements.

Patroit Lightning Arrester for Solar Systems

Solar installations require both lightning protection and electrical surge protection considerations.

A solar photovoltaic system may be exposed to lightning-related risks because of rooftop equipment, elevated mounting structures, open-field installations, and extensive electrical cabling.

For solar projects, lightning protection may involve:

  • External lightning protection systems
  • AC surge protection devices
  • DC surge protection devices
  • Earthing and bonding
  • Solar mounting structure protection
  • Lightning protection design

A Patroit ESE Lightning Arrester may be considered for external lightning protection of suitable solar installations.

However, an ESE lightning rod is not automatically a replacement for DC or AC Surge Protective Devices (SPDs). A complete solar lightning protection design should evaluate both external lightning interception and internal surge protection requirements.

This distinction is important for solar installers, electrical consultants, and EPC contractors in Pakistan.

Patroit Lightning Arrester Supplier in Pakistan

Electric Power Engineering (EPEPK) is a supplier of electrical, solar, earthing, and lightning protection products in Pakistan.

We supply Patroit ESE Lightning Arresters, including PRO and ECO+PLUS product models, for commercial, industrial, institutional, and infrastructure projects.

Our supply services include:

  • Patroit lightning arrester supply.
  • Product quotations.
  • Technical product information.
  • Project-based product assistance.
  • Lightning protection equipment sourcing.
  • Nationwide supply support in Pakistan.

Electric Power Engineering serves customers across Pakistan, including Lahore, Karachi, Islamabad, Rawalpindi, Faisalabad, Peshawar, Multan, Sialkot, and other cities.

For project requirements, customers can contact EPEPK for product availability and quotation information.

Why Buy Patroit ESE Lightning Arrester from Electric Power Engineering?

Selecting a genuine product supplier is important when purchasing technical electrical equipment such as lightning protection systems.

Electric Power Engineering provides:

  • Genuine Product Supply
  • Technical Product Information
  • Multiple Patroit Models
  • Nationwide Pakistan Supply
  • Electrical Product Expertise

Request Patroit Lightning Arrester Price and Quotation

Looking for a Patroit Lightning Arrester Price in Pakistan, technical specifications, or a suitable model for your building or industrial project?

Contact Electric Power Engineering for product availability, quotations, and technical product information.

Frequently Asked Questions About Patroit ESE Lightning Arrester

What Is a Patroit ESE Lightning Arrester?

A Patroit ESE Lightning Arrester is an Early Streamer Emission active lightning rod designed to form part of an external lightning protection system for buildings and structures.

What Is the Price of a Patroit Lightning Arrester in Pakistan?

The price depends on the selected Patroit model, protection radius, installation requirements, and project specifications. Contact Electric Power Engineering for a current quotation.

What Is the Coverage Area of a Patroit ESE Lightning Arrester?

The coverage area depends on the model, installation height, protection level, and building design. Patroit technical brochures provide model-specific protection radius values based on a 5-meter installation height.

Can Patroit Lightning Arrester Be Used for Solar Systems?

A Patroit ESE Lightning Arrester may be considered for external lightning protection of solar installations. However, solar projects may also require AC and DC surge protection devices, earthing, and bonding as part of a complete protection design.

Reviews

Reviews

There are no reviews yet.

Be the first to review “Patroit ESE Lightning Arrester Pakistan”

Your email address will not be published. Required fields are marked *